0
Programmi:
Lingua:

National annexes

These partial factors are applied for design standard EN 1995-1-1 and its annexes:

Factor

EN 1995-1-1

Czechia

Slovakia

Poland

γM - solid timber

1,30

1,30

1,30

1,30

γM - glued laminated timber

1,25

1,25

1,25

1,25

γM - accidental situations

1,00

1,00

1,00

1,00

These partial factors are applied for design standard EN 1995-1-2 and its annexes:

Factor

EN 1995-1-2

Czechia

Slovakia

Poland

γM,fi - fire resistance

1,00

1,00

1,00

1,00

Prova il Software FIN EC. Gratuitamente, senza limitazioni di analisi.