Factor

EN 1996-1-1

Czechia

Slovakia

Poland

γM - Units of Category I, designed mortar

2,0

2,00 (2,50)

2,00

1,70

γM - Units of Category I, prescribed mortar

2,20

2,20 (2,70)

2,20

2,00

γM - Units of Category II, any mortar

2,50

2,50 (3,00)

2,50

2,20

Values in brackets for the national annex "Czech Republic" are used for aac units.